LIPS massflow meter

LIPS massflow meter

Massflowmeter in the control panel housing

Bild des Durchflusstransmitter LIPS

The massflow meter LIPS for panel mounting is available with measuring ranges from 10 Nml/min to 3000 Nml/min.

Overview

  • Processor controlled linearization
  • Taring at the push of a button
  • Bidirectional USB communication
  • Large LCD display
  • 5 selectable units
  • 6 gas standards switchable
  • 9-stage damping
  • Bluetooth interface (optional)

Description

The devices of the LIPS series are mass flowmeters based on the calorimetric (thermal) principle and were specially designed for installation in switchboards. The devices have a large, illuminated graphic LCD for displaying the measured value, as well as an analog current or voltage output.
Based on the robust and highly precise electronics of the BOREAS series, we have developed the LIPS as a measuring device that can convince through its extensive equipment, high accuracy and versatility. Thanks to temperature-compensated sensors and state-of-the-art process technology, the measuring curve of these devices is linearized and achieves the excellent accuracy that is characteristic of all mensaura flowmeters. For bidirectional communication, a USB port is available, via which the devices can be configured and remote-controlled. In addition, the USB port of the digital serial output of the measured value is used. This is made possible by an integrated USB-serial converter, which can be addressed under various operating systems with free software. The devices can be tared at the push of a button, using software or via an externally connected button. An adjustable 9-stage damping serves to calm the display in the case of unsteady or pulsating flows.
The devices of the LIPS range offer the possibility to switch the unit of the measured value via a button or via the software. For this purpose, four additional units are available in addition to the basic unit “mln / min”. The devices of the LIPS series are calibrated according to DIN1343 with air (0 ° C and 1013mbar), but a total of six different gas standards can be selected by software. The illuminated display, various analogue output signals as well as the standard USB connection leave nothing to be desired when handling the LIPS.

Options

Current output 4…20mA
Digital output Bluetooth, virtual com-port

Technical specifications

Device name

Model name

Order number

LIPS

LFT2

82.xxx

Measuring ranges
  • 10 Nml/min
  • 20 Nml/min
  • 30 Nml/min
  • 100 Nml/min
  • 200 Nml/min
  • 300 Nml/min
  • 1000 Nml/min
  • 2000 Nml/min
  • 3000 Nml/min
Accuracy ± 1% rd. + 0,5% fs.
Dynamics 1:10 (10…100%)
Resolution (switchable) 0,001 / 0,01 Nml/min

0,01 / 0,1 Nml/min

0,1 / 1 Nml/min

0,001 / 0,01 Nml/min

0,01 / 0,1 Nml/min

0,1 / 1 Nml/min

Additional selectable units l/h, cm³/min, cm³/sec, in³/min
Adjustable gas standards
  • Din 1343 – (1013mbar / 0°C)
  • Din 102 – (981mbar / 20°C)
  • 936mbar / 20°C
  • 1013mbar / 20°C
  • 760mmHg / 25°C
  • ISO 2533 – (1013mbar / 15°C)
Sensor technology Unidirectional sensor,

temperature compensated

Flow direction Only positive flow

Calibrated at DIN 1343

 

Get the complete data sheet here: Data sheet – LIPS

Operating instructions, software and further downloads can be found here.

Ruequest a quote

Contact us right here.